IIssue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. MPN. 付属されていた新しいドライバCDはインストールしましたでしょうか?. It's very dangerous,my compents are allways hit. hwdb Marcel Holtmann holtmann at kemper. 您可以按照以下步骤配置运动控制器并测试步进电机:. I am using a PCI-7344 motion controller to control a slide and motor system. But the MAX couldn't read the current traject. Axis 1 is working fine, i can control perfectly the motor, I. National Instruments - PCI-7344 repair options: Standard Repair - Up to 10 workings days* Emergency Repairs - Up to 3 working days. The 7344 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 The 7344 controllers are high-performance controllers for PCI, PXI. We need to AND this output with one of the DIGITAL OUTPUT PORT of PCI 7344 . Issue Details. 5をインストールし、PCI-7344を正常に認識しました。Motion Assistant 1. 5f1. . ) angle. I am using LabVIEW 2014 and NI PCI 7344(motion controller). PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. I am using axis 3 with encoder 1 as the primary feedback, and as the control output. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. But the MAX couldn't read the current traject. The fact is ,as most say,the driver is not suitable under non-windows systems. Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. I don't see a good way to control 5 motors with this board. [systemd-commits] hwdb/20-OUI. . 00 shippingSolved: I install NI PCI-7344. But when it comes to the analog output from UMI7774, i can't measure any signal from there while i am sending commands from. The total. The PCI 7340 (4 axis) board is a drop in replacement for the PCI-7344. The Servo drive has these signals: /S-ON (Servo ON input) ALM+ (Servo alarm output) ALM (Servo alarm output) The UMI-7774 on its Control Connector of Axis1 has these signals: Enable. . Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. The DISABLED LED of the Axis1 - Axis4 on the e UMI is not Lit, i also notice that in MAX under Motion IO setting, the "inhibit input setting" is grayed. The 7334 controllersThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 02 seconds. Mark as New; Bookmark. So the servo's torque reaches the target, it shoud be stopped at that postion unless any change in servo's torque happens. This will allow you to change the board ID for your hardware so that you can use it to match the configured ID in your code, or. In the second part, you. The PXI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space. I triggered the Measures over RTSI0 with 50Hz(for a. To perform a simple move in Measurement and Automation (MAX) is very simple. National Instruments PCI-7344. I'm testing angle sensors whose voltage output is proportional to (you've guessed it. 2. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. 08-10-2007 01:26 AM. 7)and NI-DAQ 7. Especially, the hardware upgrade option is something great. For a blended move you need to use Start Motion only for the first move and Blend Motion for all consecutive moves. vi files are not running properly due to this " illegal board ID". We updated our computer and now my actuators will not move. 3. hwdb hwdb/20-usb-vendor-model. I would appreciate if you can suggest me any research that I could do on this system which involve 3 axes motion -using all ac servo motor (automated storage and retrieval system) - I. The program for our instrument is written with Labview 6 and we cannot afford to rewrite it. This makes the motor really hot. 20. vi as a starting point, I programmed my data acquisition vi to start when the Check Blend Complete. Re: PCI-7344 motor interfacing help. 75 ms corresponding to 180 degrees. 10 NI UMI 7765 Universal Machine Interface Card 38 xu . command This is one of the commands described below. I have a 3-axis robot with 3 orthogonal axes. Also I want to acquire velocity and the data from DAQ card in the same scan rate. 2 version but I can't be initialize the motion card in MAXDiscontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. I would like know if PCI-7344 Stepper/Servo Motion Controller performs electronic camming. The pulse should last from 1. Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Instruments PCI-7344 (Part number: 778916-04) is a high-quality Motion Controller for stepper/servo control applications. In addition, a PCI network card connects this MPVIEW to the Internet through the local area network (LAN). The 7344 uses a 10. (NI). Hardware Using the existing Rhino Robotics Ltd. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. When I set it up with the Ni-7344 the drive is ready (green led on drive flashes). いつもお世話になっております。 daqの外部クロック読み込みについて質問があります。 現在、pci-7344およびpci-7764を用いて、サーボアンプからのエンコーダ信号を読み取り、この信号を外部クロックとして、pci-6221に入力する電圧を読み取りたいと思っています。Im using a UMI-7774 and a PCI-7344 motion controller with a Compax C3 servo drive. 00 +$12. 1 were installed. Cary, NC, USA. "Reset Device" Button in MAX using PCI 7344 "Reset Device" Button in MAX using PCI 7344 Tulio. Sorry but I can't give you any further help. A Pivotal Phase 3 Randomized, Placebo-controlled Clinical Study to Evaluate the Efficacy and Safety of the sGC Stimulator Vericiguat/MK-1242 in Adults With Chronic. How to Configure Motion Controller and Test a Stepper Motor Updated Dec 20, 2022 Environment Hardware PCI-7332 PXI-7332 PXI-7334 PCI-7334 PXI-7342 PCI. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. . Page 3 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For further support. The Motion Controller Interactive Environment helps you test and debug your system using your current initialization settings. I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. 75 ms corresponding to 180 degrees. My DAQ is set as device 2 and my motion controller is set as board 1. 08-21-2009 03:04 PM. Featured with advanced motion control, handy software tools, and motion VI libraries (to be used with LabVIEW), the NI PXI-7344 (Part Number: 777935-01) is a 4-Axis, PXI Stepper/Servo Motion Control Module. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The PCI‑7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. SCARA and the locally fabricated driver, we can keep costs to a minimum. I recently upgraded to MAX version 2. PCI-7344 National Instruments PCI-7344 National Instruments Module Clips Drive controller servo motor Contact: Mr. Motion control (52 pages) Controller National Instruments 7344 Series User Manual. 5,控制方式采用的是位置控制模式. Find many great new & used options and get the best deals for National Instruments PCI-7344 Servo Controller Card at the best online prices at eBay! Free shipping for many products!Re: LabVIEWアップデートに伴うPCI-7344のエラー. Regards, Giridhar Rajan, Automation Engineer Cruiser Controls Mumbai, IndiaThe cheapest NI board that supports elliptical moves in contouring mode is the PCI-7342. 3. Go to the Axis Configuration option, under the desired axis (e. The Problem is feedback from each axis (AZ & EL). Periodically the servo system does not work. This was a problem at first, because the amplifier is intended for differential outputs, while my encoders have single. comPXI-7344. option from the right-click menu. Configure your stepper settings. Problem 2 The position does not automatically reset to zero when the z. I don't need a visual indi. umi-7764/7774をステッピングモーターメーカーのモータードライバに接続して使おうとしています。モータードライバはフォトカプラ入力になっています。どのように接続したらいいですか?From MAX, select your PCI-7344 under NI Motion Devices. Now I have used to VI PWm duty and config PWM. rules. 01-30-2006 10:29 AM. Regards Sudhir Sawant Emai. I have neither asked for nor received a calibration certificate for a PCI-7344. Product Support Resources. But. 4-Axis, Stepper Motion Controller Device—The PCI‑7334 is designed for point‑to‑point motion applications. 问题:. Please provide me with a Letter of Volatility for the Motion Control Boards PCI-7344 and PCI-7354. 2: I wrote an onboard program that makes a 2axis move and one/two onboard program(s) that write with HighSpeedCapture the Positions to a buffer. 2. To guarantee the delay-free commands flow we use the programmable FPGA device present on the NI-Motion PCI-7344 stage controller board. PCI-7390 Driver. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. . This warranty includes parts and labor. zip" has been downloaded 223 times with a user rating of 5 out of 5 stars, based on 10 reviews. If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The system works ok, except I have no control over the velocity (does not respond to the vel input vi) as well as there is some hysteresis in the system that provides a large deadband area in the operation about the point where the. Motion Control 7344/7334 Hardware User Manual 7344/7334 Hardware User Manual May 2001 Edition Part Number 322504B-01. Options. Options. What would it take to build. The cards do not work on a Computer with differen Hardware, nor when the operating system is Windows XP. Go to the Axis Configuration option, under the desired axis (e. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. controller in the 7344 family and contains information concerning their operation and programming. . I have no choice in using synchro's as feedback. Now i´m using the PCI-6527 board and simulating the delay between "high" and "low" on the Simulate-signal-vi. Can i have solution for this . 8 degree pitch (200 steps per rev). But the MAX couldn't read the current traject. I am seeing the PWM waveform on CRO. Order toll free: 800. 1) When I am stationary and command a Halt, there is a resulting jerk movement, sometimes up to a few 1000 servo steps. 我目前的系統是PCI-7344 + UMI7764 LabVIEW 8. it is going to be sqaure wave signal . また、NIのホームパージから. If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. To do so, I would like to write a simple C program to, every specified sampling time T, do the followings: read encoder, calculate output. The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. For my research purpose I need some important information from you. When i am using PCI Flex-6C,Finding home functions does not work as the PCI 7344 do, The controller stops axis 1 and axis 2 during the finding home sequences when the axis 3 encountered home switch first. Overview of the 1-D Interactive Panel. Any help is appreciate. Manufacturer: National Instruments; PCI-7344, 4-Axis, Motion Controller National Instruments PCI-7344 Motion Controller DeviceFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Inst. 25 ms corresponding to 0 degrees, 1. You won't be able to achieve these types of signals with a 7344 motion control board. I am a Master’s student of International Islamic University Malaysia. I am using a 4096 step per revolution encoder with a UMI-7764 connected to a PCI-7344. Dear Engineers, Now we are useing PCI7344 on motor-controlling. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. Refer to the Glossary section of this manual for definitions of selected related terms. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. Re: PCI7344 and Copley Accelus Drive. National Instruments PXI-7344, 777935-01. I would like to implement control algorithm on PCI 7344 (Don't want to use the built-in PID). de * Technical Support for Motion SoftwareI'm not sure what you mean by voice coil, but the UMI 7764 is designed to interface with third party amplifiers to drive motors. Unfortunately my FW-7344 has malfunctioned and my supervisor has asked me to research other options to have it replaced. The 7342 follows this position profile using a spline algorithm. In order to make the encoder work again, I need to do a complete shutdown. flx) to trigger a move (Start Motion. At Lektronix we can provide you with a brand new National Instruments PCI-7344 covered by the Original Manufacturers Warranty. The 7344 can do a frequency of 40 Hz or 78 Hz (which either. Use a higher resolution encoder. We have two linear servohydraulic actuators for applying linear force to tie rod and a servo motor for steering wheel movement. . This warranty includes parts and. 10-27-2001 03:20 PM. The 7342 follows this position profile using a spline algorithm. I'm programming a 3-axis piezo stage to do fast scanning (128x128 points in ~ 5 seconds) with a PCI-7344. 4-Axis, Stepper/Servo Motion Controller Device4-Axis, Stepper/Servo PXI Motion Controller Module —The PXI‑7344 is recommended for both simple and complex motion applications. 2. nce-file would it be possible to do the same thing with a C Series Motor Interface Module that uses the SoftMotion driver such as the NI 9514?PCI-7334 PCI-7344 Software. When i try to autotune, the servo motor goes berserk, so I have to manually tune it with "Step response". The NI Motion drivers with the 7344 motion controller are not capable of that type of control. FlexMotion 5. 展开 默认 73xx 设置 树. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and you. Options. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 [email protected] there, I would like to trigger my piezoelectric motor more than 100Hz, can I do that with motion controller PCI-7344/PCI-6036E and using while Return to Home Page Toggle navigationThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. I. Hello, After having configured mu board PCI-7344 under MAX software (1axis activated because 1 only axis used, standard of stepper in open Loop. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334. At times we have seen commands to one axis result in another axis moving. The "Encoder Index found" led is green. 75 ms. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. Software Changes: All of these settings are at Device and Interfaces >> NI-Motion Devices >> Default 73xx Configuration >> Axis x >> Axis Configuration >> Stepper Settings . (The servo drive manual is here:The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. . used. This means you can create a position profile and download these contouring data to the PCI-7342. Axis 1) In the Axis Configuration tab, set Type to Stepper. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 0 Kudos Message 1 of 3 (5,141 Views) Reply. Lai Wechat:17750010683 Whats app:+86 17750010683Hello, I am fairly new to LabVIEW and was wondering how to implement incremental rotary encoders into a motion control VI. Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). i just need to know if what i write here is correct. supoose in my . いつもお世話になっております。 現在,MAX上でモータのチューニングを行っているのですが,以下の4点について教えてください。 (motionボードはPCI-7344,UMIはUMI-7764を用いています) 1,Axis ConfigurationでTypeをServoとした場合に, どのような信号でモータの回転方向(正回転,逆回転)および速度. The NI-Motion version is 7. You willI have a E-Stop button on my machine. The 7344 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 The 7344 controllers are high-performance controllers for PCI, PXI. 5500. An introduction to the National Instruments PCI-7344 Motion ControllerFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID. I would like to implement the same thing using FP & Softmotion instead of 7344 board as later I would like to implement fuzzy logic control into softmotion. The 10 ms timing for contoured move is the fastest that you can get out of the board. Chapter 5 Signal Connections Analog Inputs The 7344/7334 controller has the following ADC input signals: • 7344/7334 Hardware User Manual Analog Input <1. National Instruments PCI-7344. Along with this, I want to record motion/motor position data into the same file, whenever I give a move (sinusoidal) command. I am a Master’s student of International Islamic University Malaysia. Hi all, I'm using the PCI-7344 board and I'd like to trigger an external device. 3. 0) hangs. the PCI-7344 can control up to four axes. 8. 6: Cấu trúc của máy phay CNC. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. PCI-7344 PCL812PG TRỤC CHÍNH BÀN MÁY CHI TIẾT LỰC KẾ Hình 1. 1. Hi, We have a MID7654/7652 servomotor power drive, a PCI 7344 motion control card and Flexmotion software. Re: a problem with Flex-6C controller MarcoPolo5. Figure 7. It is related to 3D printer. Mark as New;. SoftMotion is a great alleviation as you can. flx and Read Trajectory Data. Mid-Range Stepper/Servo Motion Controllers 2 AMC GmbH Chemnitz * Tel: 0371/38388-0 * Fax: 0371/38388-99 * [email protected] PCI-7344 with LabView for use as a Parabolic Antenna controller. Why would the Blend Complete bit get set rather than. It takes 10-20 milliseconds to start the move after the trigger. I am using a PCI-7344 card with LabView to control a 3-axis servo motor motion system in conjunction with a data acquisition system. I met a problem in using the Labview and it is extremely urgent (I have to make it work in 24hrs). I can commuunicate with the drive using it own software. This warranty includes parts and labor. If I set the blend factor to 0 or larger values, the sharp corners reserve, but it seems that we h. The PCI-7342 supports buffered contouring mode. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. 1) connected to a MID-7604 drive to control three IDC P21T stepper motors. Depending on the movement of a xy - stage (controlled by the motion controller) I'd like to trigger a laser pulse. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. 10. It offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high. ) Issue: W. 1) connected to a MID-7604 drive to control three IDC P21T stepper motors. In our normal system, we use 16 or 12 bit S/. 1. We built the entire machine to industrial standards for ruggedness, reliability, and minimal down time. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. I make apply the parameters followed by the stage Initialisation and the motor is. JB. I am trying to figure out the best way to calibrate encoders with the PCI-7344 interface card. 6 on a separate desktop system with a PCI-7344 motion controller and a PCI-6221 DAQ card. This works fine while no other process on the PC is running. The x- and y-axes of the Cartesian robot used a timing belt while the z-axis utilized a ball screw. Using PCI-7344 and MID-7604 and FLEXMOTION. The parameters of that algorithm can be modified, but the algorithm itself is fixed. The onboard CPU uses an embedded real-time OS. If you have non-plug and play (ISA bus) boards, refer to the ISA Installation (PC-FlexMotion-6C Only) section of this document. Essential details:PCI-7344 NI Motion Controller Device Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National. Hi all, I'm using the output pins of the 7344 - board. And see the result. In our system, a high resolution encoder works as the feedback sensor, and a third-party of servo works as the velocity loop controller. Shipping and handling. Manufacturer: National Instruments FW-7344, 4 Axes, 9 to 25 VDC, Stepper/Servo Motion Controller National Instruments FW-7344 Stepper/Servo Motion Controller The FW-7344 (Part Numbers: 186839C-01, 778113-01) is a Stepper/Servo Motion Controller. jspaarg. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. . 1. Shut down your computer. また、NIのホームパージから. Network, share, and ask questions with other members of the NI community. 2のインストールを行うと、Measurement and Automation Explorer (MAX)にデバイスが表示されなくなりWindowsのデバイスマネージャーでもpci‑7344为嵌入式实时运动操作或以主机为中心的编程环境提供了混合运动轨迹控制和完全协调的圆形、线性、点对点、齿轮和矢量空间控制。 pci‑7344还为复杂运动提供了轮廓控制功能。 板载cpu采用嵌入式实时操作系统,可进行基于事件的多任务控制。. I know there is in flexmotion library the : Initialize controller. These devices run the PID loop onboard in realtime and you only need to set parameters like travel distance, speed and acceleration. The change was part of an improvement to the manufacturing process for. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and. We were. 0 system with the newest NI-Motion 7. Restart and reinstall the drivers for NI-Motion - this will also add MAX. Seller assumes all responsibility for this listing. We presented a solution using the NI PCI-7344 four-axis stepper and servo motion controller using LabVIEW as the main user interface. Thank you for your reply !! I am developing pci-7344`s driver under venturecom`s rtx,now I have found the baseadresses[0] and baseadresses[1] . I have no choice in using synchro's as feedback. Pxi-7344 provides hybrid motion trajectory control and fully coordinated circular, linear, point-to-point, gear and vector. 7350 and 7340. The onboard CPU uses an embedded real-time OS. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. Under this section select the settings option (by default it will be called Default 7340 settings). Feedback is a incremental encoder 16404counts/rev (400counts/mm). 1. Martin Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. The Motion driver with the PCI 7344 has its own algorithm in place. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. You may be having what is the major reason not to use global variables - a race condition. 14 PC-Based System with FP 2000 Hardware Configurations 42. Options. 12-10-2002 05:13 AM. 1 asks for firmware upgrade. Starting on page 5-9. used. In our normal system, we use 16 or 12 bit S/. pci-7340 initialization problem mechanical Engineer. Unless otherwise noted, text applies to all controllers in the 7344 family. Hello, I really really need help in this: I have UMI 7774 and PCI 7344 and i have problems to Connect it to my Servo Motor Drive. National Instruments PCI-7344 4-Axis Stepper/Servo Controller Card This unit ships sealed in the manufacturer's static bag. . I've been using NI, PCI-7344 motion controller. 25 ms to 1. また、NIのホームパージから. 問題: 我嘗試要重設位置,但是總是不會歸零。 我的位置總是會被重設到零以外的數值,我該如何將它變為零. I have various operations to perform that would be a lot easier if i had the ability to define local coordinate systems by specifying origin, vectors, planes, points, et. The onboard CPU uses an embedded real-time OS. The PCI‑7344 also provides contouring capability for complex moves. 2) I manaully turned a motor and read back the positions through 1-D Interactive are between arou. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. The PCI‑7344 also provides contouring capability for complex moves. In Windows Device Manager, right-click on the PCI Simple Communications Controller and select Properties . The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. After I issue an absolute move on a closed loop stepper axis with PCI-7344 using flex_Start, the Move Complete bit never gets set, but the Blend complete bit does. 0. We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. Ca hai ho tr ay u viec lap trnh ieu khien chuyen ong cho phep ieu khien toi a 4 truc ong thi va oc lap. 9 PCI 7344 Motion Card Component Interaction 37 3. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. 13 NI FP 2000 Hardware Platform Set up 41 3. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. But i >want to do it automatically in a VI. Remote Printing. However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. 1 asks for firmware upgrade. Options. However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. 05-10-2006 05:05 PM. But to my surprise the output is not matching the required data. Worldwide Technical Support and Product Information National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100The PCI-7344, PXI-7344, PCI-7334, and PXI-7334 controllers are fully compatible with the PCI Local Bus Specification, Revision 2. Solution. ), I configure a sequence (in the sequence tab"Find Reference Settings )that the motor finds my" home switch ".